Central temperature management node to prevent overheating and optimize noise levels.

- Fan Operation Mode:
- Auto: The firmware automatically adjusts fan speeds based on chip temperature. This is the safest mode.
- Manual: Fan speed is set to a fixed PWM level (e.g., 40%, 70%, 100%) regardless of temperature.
- Immersion: Fans are completely turned off for liquid immersion operation; control is based on liquid heating (inlet-outlet).
- Target Temperature: Sets the chip temperature (recommended value — 65°C) that the system will maintain by adjusting fan speeds.
- Minimum Number of Fans: Specifies the number of fans that must be operational (default — 4).
- Fan Speed Limit: A slider to restrict the fan power range in percentages (from 10% to 100%).